DRE Echo CO2 Capnograph Monitor

(800) 499-5383

0 items are in your cart. View cart now.

Web ID: 18224

Need Advice?

Ask Our Experts! (800) 499-5383

Payment methods

Secure Express Checkout

Save your payment information securely using Stripe for express checkout.

Description

Effective Capnography Monitoring.

The DRE Echo CO2 provides cost-effective SPO2 and CO2 monitoring with accuracy and durability. The Echo CO2 ensure effective capnography monitoring for intubated and non-intubated patients for continuos long term monitoring. It is tailored for mechanically ventilated and non-intubated patients.

FEATURES

  • 5.7 inch high resolution display for easy reading
  • Lightweight, portable design and user-friendly interface
    for easy operation
  • Flexible configurations to meet different clinical needs
  • Standard SpO2
  • PR measurement
  • Respironics Loflo sidestream and CAPNOSTAT 5
    ETCO2 mainstream measurement
  • Real-time parameters measurement display
    with trend table for easy reviewing
  • Built-in rechargeable Lithium-ion battery for
    10 hours continuous working
  • Powerful storage capacity
  • Bi-directional communications with central station by
    wired or wireless network
  • Nurse call
  • Suitable for adult, pediatric and neonatal patient

SPECIFICATIONS

Technical Specifications

  • Size: 200.8mm (L) x 241mm (H) x 189 mm (D)
  • Weight: 3 kg
  • Display: 5.7 inches
  • Color TFT resolution: 640X480
  • Power Supply: 100-240 VAC, 50/60HZ
  • Pmax=70VA FUSE T 1.6AL
  • Battery Type: Lithium-ion
  • Voltage: 14.8 V DC Capacitance: 4,400 mAh
  • Working period: Color TFT 480min
  • Rechargeable period: < 360min
  • Thermal Recorder: (Optional)
  • Record Width: 48 mm
  • Paper Speed: 25mm/s

SpO2

  • Measuring Range: 0 ~ 100 %
  • Alarm Range: 0 ~ 100 %
  • Resolution: 1 %
  • Accuracy
  • Adult (including Pediatric)
    ± 2% (70%~100% SpO2)
    Undefined 0~70% SpO2
  • Neonate
    ± 3% (70%~100% SpO2)
    Undefined (0~70% SpO2)
  • Pulse Rate
    Measuring and Alarm Range: 30 ~ 300bpm
    Resolution: 1bpm
    Accuracy: ± 3bpm
    Data update period: 2s
    ISO 9919

Respironics CO2

Mainstream

  • CO2 Measurement Range
    0 to 150 mm Hg,0 to 19.7%,
    0 to 20 kPa (at 760 mm Hg)
  • Rise Time
    Less than 60 ms Adult/Infant
    Reusable or Single Patient Use
    Airway Adapter
  • CO2 Resolution
    0.1 mm Hg -- 0 to 69 mm Hg
    0.25 mm Hg -- 70 to 150 mm Hg
  • CO2 Accuracy
    0-40 mm Hg -- ±2 mmHg
    41 - 70 mm Hg -- ± 5% of reading
    71 - 100 mm Hg -- ± 8% of reading
    101 - 150 mm Hg -- ±10% of reading
    Above 80 bpm -- ±12% of reading
  • CO2 Stability
    Short Term Drift: Drift over four hours shall
    not exceed 0.8 mm Hg max.
    Long Term Drift: Accuracy specification will
    will be maintained over a 120-hour period
  • Respiration Rate Accuracy
    ±1 breath
  • Calibration
    No routine user calibration required. An
    airway adapter zero is required when
    changing to a different style of airway adapter
  • Water Resistance
    IPX4-Splash-proof (sensor head only)
  • Shock Impact
    EN60068-2-6 Sinusoidal Vibration
    EN60068-2-27 Shock
    EN60068-2-64 Random Vibration
    Able to withstand repeated 6 foot drops onto tiled floor while operating

Sidestream

  • Sample Rate: 50 m/L per minute
  • CO2 Measurement Range:
    0 - 150 mm Hg, 0 to 20 kPa
    (at 760 mm Hg). Barometric Pressure
    supplied by Host
  • CO2 Resolution:
    0.1 mm Hg 0 to 69 mm Hg
    0.25 mm Hg 70 to 150 mm Hg
  • CO2 Accuracy
    0 - 40 mm Hg ±2 mm Hg
    41 - 70 mm Hg ±5% of reading
    71 - 100 mm Hg ±8% of reading
    101 - 150 mm Hg ±10% of reading
    Above 80 bpm ±12% of reading
  • CO2 Stability
    Short Term Drift: Drift over four hours shall
    not exceed 0.8 mm Hg max.
    Long Term Drift: Accuracy specification will be
    maintained over a 120-hour period
  • Respiratory Rate Range: 2 to 150 bpm
  • Respiratory Rate Accuracy: ±1 breath
  • Sample Cell/Filter
    Proprietary single patient use sample cell and
    inline filter are integrated with the sample
    line which eliminates contamination of the
    internal system
  • Nasal Sampling Kits for Non-intubated Patients
    Adult, pediatric and infant nasal CO2
    sampling, nasal CO2 sampling and O2 delivery
    Adult and pediatric nasal/oral CO2sampling,
    nasal/oral CO2 sampling and O2 delivery
  • On-Airway Adapter KITS for Intubated Patients
    Adult/Pediatric with and without
    dehumidification tubing Pediatric/
    Infant, low dead space, with and without
    dehumidification tubing
    Taper meets ISO 5356-1
  • Sample Kit Hours of Use
    Nasal Cannula (all styles) ¢¢€š¬” up to 12 hours
    On-Airway Adapter Kits without
    dehumidification tubing ¢¢€š¬” up to 12 hours
  • Sample Cell Detection
    Insertion automatically turns sampling pump
    on. Removal automatically turns sampling
    pump off.
  • Water Resistance IPX4 -Splash-proof
    (when sample cell is inserted in sample
    cell receptacle)
  • Shock ImpactIEC TR 60721-4-7 Class 7M3
    (designed to withstand environments subject to significant
    vibrations or high shock levels)
    EN60068-2-27 Shock
    EN60068-2-64 Random vibration

Specifications subject to change without notice.